Anesthesia-System-MD-ANS-1001


Coraldean1104

Uploaded on Apr 10, 2025

Category Technology

MedicalDeals Anesthesia System offers precise respiratory control with a positive end-expiratory pressure range of 0 to 30 cmH2O. It supports IPPV, Assist Control, Synchronized Intermittent Mandatory Ventilation, Sigh, and Manual modes. Features include a 7-inch LED display and rapid oxygen delivery.

Category Technology

Comments

                     

Anesthesia-System-MD-ANS-1001

Anesthesia System MD-ANS-1001 Overview : Anesthesia System MD-ANS-1001 provides a Positive End Expiratory Pressure range of 0 to 30 cmH2O. It provides a versatile ventilation parameter range of tidal volumes from 20 mL to 1500 mL. This advanced system offers a variety of ventilation modes and adjustable parameters. It also provides a wide frequency range ensuring precise control and customized care to meet the needs of each patient. Our anesthesia system is a highly efficient and adaptable solution ideal for anesthesia and critical care settings. Features: Oxygen sensor Versatile Ventilation Modes 7-inch LED display ACGO and Fast Oxygen supply Precise Control of Respiratory Parameters Advanced Alarm System Comprehensive Monitoring Oscillogram Display Built-in backup battery 2-3 hours backup battery Emergency and revival after operation Compact and Durable Design Standard accessories: Anesthetic breathing system × 1 Power cord × 1 Fuse × 8 Fuse × 1 Fuse × 2 O cell × 1 2 CO sensor 2 Breathing tube × 2 Breathing tube × 2 Y connector Adult × 1 Y connector Child × 1 L connector × 2 Reservoir bag 1L × 1 Reservoir bag 3L × 1 Anesthetic mask adult × 1 Anesthetic mask infant × 1 Anesthesia Vaporizer × 2 High pressure O hose × 1 2 High-pressure AIR hose × 1 High pressure N O hose × 1 2 Optional accessories: Mainstream CO Sensor × 1 2 Sidestream CO Module × 1 2 Mainstream gas Analyzers × 1 Sidestream gas Analyzers × 1 CO Mainstream Module × 1 2 CO Sidestream Module × 1 2 Multi-gas Sensor × 1 Transfer and receiving system of exhaust gas × 1 Applications: Anesthesia System MD-ANS-1001 is ideal for patients who require ventilatory support, including those experiencing respiratory failure, trauma, or undergoing emergency surgeries. Specifications : Ventilation Modes IPPV, A/C, SIMV, SIGH, MANUAL Gas Source O , N O, AIR 2 2 O : 0.1 to 10 L/min; 2 Flowmeter range N O: 0.1 to 10 L/min 2 AIR: 0.1 to 10L/min Rapid Oxygen Supply Range 25 L/min to 75 L/min Oxygen Concentration 15 % to 100 % Tidal Volume (Vt) range 0, 20 mL to 1500 mL Frequency range 1 /min to 100 /min Inspiratory Ratio (I.E) 2:1 - 1:6 Minute Volume (MV) 0 L/min to 100 L/min Positive End-Expiratory Pressure (PEEP) 0 cmH2O to 30 cmH2O Pressure Triggering Sensitivity (P ) -20 cmH O to 20 cmH O (Based on PEEP) Tr 2 2 Flow Trigger Sensitivity (F ) 0.5 L/min to 30 L/min Tr SIGH 0 (off) 1/100 to 5/100 Apnea Ventilation OFF, 5 s to 60 s Gas Pressure Range 280 kPa to 600 kPa Pressure Limit 20 cmH O to 100 cmH O 2 2 Bellow 1.5L P-T (Pressure-Time), Oscillogram Types F-T (Flow-Time), P-V loop (Pressure-Volume Loop) The AC power failure alarm Power failure or no connection Alarm for backup battery 11.3 ± 0.3 V No tidal volume ? 5 mL within 6 s High oxygen concentration alarm 19% to 100% Low oxygen concentration alarm 18% to 99% High airway pressure alarm 20 cmH O to 100 cmH O 2 2 Low airway pressure alarm 0 cmH O to 20 cmH O 2 2 High-minute volume alarm Adult (5 L/min - 20 L/min) Low-minute volume alarm Paed (1 L/min - 15 L/min, 0 - 10 L/min) Continuous pressure alarm (PEEP+1.5 kPa) over 16s Suffocation warning 5 s – 60 s no spontaneous ventilation The maximum limited pressure 12.5 kPa Fan error Shows on screen Oxygen deficit Shows on screen Display 7-inch LED screen Power Consumption 40 VA Power Supply Voltage: 100 to 240 V Power Frequency: 50/60 Hz Packing Dimension 760 × 970 × 1550 mm Net Weight 82.5 kg Gross Weight 143 kg 156 Great Charles Street, Queensway, Birmingham, West Midlands B3 3HN, Uk Email: [email protected] | Website: www.medicaldeals.com | Phone: +1 506 699 0674