Anesthesia-System-MD-ANS-1003


Coraldean1104

Uploaded on Apr 10, 2025

Category Technology

MedicalDeals Anesthesia System offers a rapid oxygen supply with flow rates adjustable from zero to ten liters per minute. It supports ventilation modes such as intermittent positive pressure ventilation, synchronized intermittent mandatory ventilation, and manual modes for versatile patient management.

Category Technology

Comments

                     

Anesthesia-System-MD-ANS-1003

Anesthesia System MD-ANS-1003 Overview : Anesthesia System MD-ANS-1003 features a rapid oxygen supply with adjustable flow rates from 0 to 10 L/min. It has multiple ventilation modes, including IPPV, A/C, PCV, SIMV, SIGH, and manual. It offers a high-precision flowmeter for immediate, accurate monitoring of fresh gas flow. The ventilator operates with a versatile range of tidal volumes from 20 mL to 1500 mL, with a frequency of 1 to 100 breaths per minute. Our Anesthesia System ensures enhanced safety and flexibility ideal for anesthesia and critical care settings. Features: Instant and accurate monitoring Adjustable oxygen flow rate Adjustable PEEP Comprehensive Pressure control settings Adjustable Breathing Frequency Integrated breathing circuit design 10.4" TFT LCD screen display High precision flowmeter Patient-centered ventilation Low-pressure alarm cut-off protection. Compact design Standard accessories: Anesthetic breathing system × 1 Power cord × 1 Fuse × 2 Fuse × 1 O sensor × 1 2 Breathing tube × 2 Breathing tube × 1 Breathing tube × 2 Y connector Adult × 1 Y connector Child × 1 L connector × 2 Straight connector (?22 to ?22) × 1 Reservoir bag 1L × 1 Reservoir bag 3L × 1 Anesthetic mask adult × 1 Anesthetic mask infant × 1 Anesthesia Vaporizer × 1 High pressure O hose × 1 2 High-pressure AIR hose × 1 High pressure N O hose × 1 2 Optional accessories: Transfer and receiving system of exhaust gas × 1 CO Sensor × 1 2 Patient monitor × 1 Applications: Anesthesia System MD-ANS-1003 delivers exceptional performance in (ICUs), operating rooms, and other clinical settings, this machine offers top-tier safety, stability, and user convenience, ensuring an excellent experience for clinicians. Specifications : Ventilation Modes IPPV, PCV, A/C, SIMV, SIGH, MANUAL Gas Source O , N O 2 2 O 2: 0 to 10 L/min; Flowmeter range 2 N O: 0 to 10 L/min 2 Rapid Oxygen Supply Range 25 L/min to 75 L/min Oxygen Concentration 15 % to 100 % Tidal Volume (Vt) range 0, 20 mL to 1500 mL Frequency range 1 /min to 100 /min Inspiratory Ratio (I) 0.2s to 6s 2:1 - 1:6 Minute Volume (MV) 0 L/min to 100 L/min Positive End-Expiratory Pressure (PEEP) 0 cmH O to 30 cmH O 2 2 Pressure Triggering Sensitivity (P ) -20 cmH O to 20 cmH O Tr 2 2 Flow Trigger Sensitivity (F ) 0.5 L/min to 30 L/min Tr SIGH 0 (off) 1/100 to 5/100 Apnea Ventilation OFF, 5 s to 60 s Gas Pressure Range 280 kPa to 600 kPa Pressure Limit 20 cmH,sub>2O to 100 cmH O 2 P-T (Pressure-Time), F-T (Flow-Time), V-T (Volume-Time) Oscillogram Types P-V loop (Pressure-Volume Loop) F-V (Flow-Volume Loop) F-P (Flow-Pressure Loop) ETCO -T (ETCO -Time) 2 2 The AC power failure alarm Power failure or no connection Low voltage alarm for backup battery 11.3 ± 0.3 V No tidal volume ? 5 mL within 6 s High oxygen concentration alarm 19% to 100% Low oxygen concentration alarm 18% to 99% High airway pressure alarm 20 cmH O to 100 cmH O 2 2 Low airway pressure alarm 0 cmH O to 20 cmH O 2 2 High-minute volume alarm Adult (5 L/min to 20 L/min) Low-minute volume alarm Paed (1 L/min to 15 L/min, 0 ~ 10 L/min) Continuous pressure alarm (PEEP+1.5 kPa) over 16s Suffocation warning 5s-60s no spontaneous ventilation The maximum limited pressure ? 12.5 kPa Fan error Show on screen Oxygen deficit Show on screen Power Consumption 85 VA Voltage: 100 to 240 V Power Supply Power Frequency: 50/60 Hz Packing Dimension 740 × 795 × 1540 mm Net Weight 52.5 kg Gross Weight 119 kg 156 Great Charles Street, Queensway, Birmingham, West Midlands B3 3HN, Uk Email: [email protected] | Website: www.medicaldeals.com | Phone: +1 506 699 0674