Anesthesia-System-MD-ANS-1007


Coraldean1104

Uploaded on Apr 11, 2025

Category Business

Medical Deals Anesthesia System offers versatile ventilation modes, including volume and pressure control options with manual support. It features a fifteen-inch TFT LCD touchscreen, built-in electronic flowmeter, self-testing compliance compensation, and precise gas flow control for oxygen, air, and nitrous oxide.

Category Business

Comments

                     

Anesthesia-System-MD-ANS-1007

Anesthesia System MD-ANS-1007 Overview : Anesthesia System MD-ANS-1007 features versatile modes like V-CMV, V-SIMV, P-CMV, P-SIMV, PSV, PCV-VG, and Manual, providing tailored respiratory support. It offers precision with tidal volumes from 10 to 1500 mL and a frequency of 4 to 100 breaths per minute. It has an I ratio of 4:1 to 1:10 controlling the patient’s ventilation. Built for durability, it comes in a protective wooden case. Our Anesthesia system ensures enhanced safety and flexibility, making it ideal for anesthesia and critical care settings. Features: 15” TFT LCD touchscreen Built-in electronic flowmeter Self-testing compliance compensation automatic compliance compensation Patient-centered ventilation Separate design ensures long use life Fresh oxygen or air Real-time monitoring Mechanical flowmeter Built-in Battery Backup Compact and Light-weight Standard accessories: Anesthetic breathing system × 1 Power cord × 1 Fuse × 8 Fuse × 1 Fuse × 2 Central O supply tube× 1 2 O2 sensor × 1 CO sensor 2 Breathing tube × 2 Breathing tube × 2 Y connector Adult × 1 Y connector Child × 1 L connector × 2 Reservoir bag 1L × 1 Reservoir bag 3L × 1 Anesthetic mask adult × 1 Anesthetic mask infant × 1 Anesthesia Vaporizer × 2 High pressure O hose × 1 2 High-pressure AIR hose × 1 High pressure N O hose × 1 2 Applications: Anesthesia System MD-ANS-1007 excels in Intensive Care Units (ICU), operating rooms, anesthesiology departments, and other medical settings, offering professional design for adult, pediatric, and neonatal inhalation anesthesia and respiratory management with advanced ventilation modes. Specifications : IPPV, PCV-PC, PCV-VG, V-A/C, P-A/C, P-SIMV, V-SIMV, PSV, PCV-VG SIGH, Ventilation Modes MANUAL Gas Source O , N O, AIR 2 2 O : 0 to 15 L/min 2 Flowmeter range N O: 0 to 12 L/min 2 AIR: 0 to 15 L/min Rapid Oxygen Supply Range 35 L/min to 75 L/min Oxygen Concentration 15 % to 100 % Tidal Volume (Vt) range 0, 10 mL to 1500 mL Frequency range 4 /min to 100 /min Inspiratory Ratio (I) 4:1 to 1:10 Inspiration Time Range 0.2 s to 5 s Minute Volume (MV) Range 0 L/min to 100 L/min Positive End-Expiratory Pressure 0 cmH O to 30 cmH O (PEEP) 2 2 Pressure Triggering Sensitivity (P ) -20 cmH O to 0 cmH O Tr 2 2 Flow Trigger Sensitivity (F ) 0.3 L/min to 15 L/min Tr Gas Pressure Range 280 kPa to 600 kPa Pressure Limit 10 cmH O to 100 cmH O 2 2 SIGH 0 (off) 1/100 to 5/100 Inspiration Apnea Ventilation OFF, 5% to 60% Trigger 5% to 95% SIMV frequency range 4 /min to 60 /min Rise time 0 s to 2 s Bellow 1L P-T (Pressure-Time) F-T (Flow-Time), V-T (Volume-Time) Oscillogram Types P-V loop (Pressure-Volume Loop) ETCO -T (ETCO -Time) 2 2 F-V (Flow-Volume Loop) F-P (Flow-Pressure Loop) High-minute volume alarm Power supply Undervoltage alarm Low-minute volume alarm Low tidal volume alarm High airway pressure alarm Continuous pressure alarm Low airway pressure alarm High-frequency alarm No tidal volume Suffocation alarm High tidal volume alarm Backup power alarm Absorber disconnection alarm Battery exhausted alarm High oxygen concentration alarm Fan error Low oxygen concentration alarm Low oxygen supply alarm High ETCO2 concentration alarm Low-frequency alarm Power Consumption 85 VA Power Supply Voltage: 100 to 240 V Power Frequency: 50/60 Hz Packaging Dimension 1005 × 960 × 1700 mm Net Weight 132 kg Gross Weight 253 kg 156 Great Charles Street, Queensway, Birmingham, West Midlands B3 3HN, Uk Email: [email protected] | Website: www.medicaldeals.com | Phone: +1 506 699 0674