Single-Channel-ECG-Machine-MD-SEM-1000


Coraldean1104

Uploaded on Apr 21, 2025

Category Technology

Medical Deals Single Channel ECG machine has a touch screen display and supports multiple languages for user-friendly operation. It functions within temperatures of 5℃ to 35℃ and up to 80% humidity. Built with floating input and defibrillation protection, ensuring safe and accurate monitoring.

Category Technology

Comments

                     

Single-Channel-ECG-Machine-MD-SEM-1000

Single Channel ECG Machine MD-SEM-1000 Overview : Single Channel ECG Machine MD-SEM-1000 operates within a temperature range of 5? to 35? and humidity up to 80%. Its high- resolution thermal printing array system operates at 75 Hz, ensuring crisp and detailed printouts of ECG traces. It is safe to use during defibrillation and has good noise control for accurate results. Our ECG Machine is equipped with a built-in rechargeable battery ensuring uninterrupted usage. Features: Single channel Touch screen display Supports multi-language Built-in rechargeable battery Auto record setup Auto-Interpretation system Auto-correct record capabilities Applications: Our Single Channel ECG Machine is used in hospitals and clinics for recording and analyzing heart activity. Specifications : Environment temperature: -10? to 55? Storage Conditions Relative humidity: ? 95% Atmospheric pressure: 50kPa to 106 kPa Environment temperature: +5? to +35? Operational Conditions Relative humidity: ? 80% Atmospheric pressure: 86kPa to 106 kPa Input Way Floating and defibrillation protection Lead Standard 12 leads Patient Leak Current 10 ?A Input Impedance ?5 M? Frequency Response 1 Hz to 75 Hz Time Constant >3.2s CMRR >60 dB EMG Interference Filter 25/35 Hz (-3 dB) Recording Way Thermal array printing system 50 mm × 20m Recording Paper Dimensions (W×L) Highspeed thermal paper Auto record: 25mm/s, 50mm/s, error: ±5% Paper Speed Rhythm record: 25mm/s, 50mm/s, error: ±5% Manual record: 5mm/s, 6.25mm/s, 10mm/s, 12.5mm/s, 25mm/s, 50mm/s, error: ±5% 2.5, 5, 10, 20,40 mm/mV Sensitivity Selections 5 options Error: ±5% Standard Sensitivity 10 mm/mV ± 0.2 mm/mV Measurement Parameters 10 mm/mV ± 0.2 mm/mV Product Safety Type Class I, Type CF defibrillation proof applied part Enduring Polarization Voltage ±300 mV Noise Level ?15 ?Vp-p Dimension (L × W × H) 207 mm × 96 mm × 62 mm Net Weight 0.5 Kg 156 Great Charles Street, Queensway, Birmingham, West Midlands B3 3HN, Uk Email: [email protected] | Website: www.medicaldeals.com | Phone: +1 506 699 0674