Try Huawei H12-425 Dumps | H12-425 Verified Question Answers


Robert114

Uploaded on Nov 25, 2020

Category Education

If you want to nail your HCIA-Data Center Facility Exam, you need to work with a feasible study plan and a useful study guide. Now you can get both of these at Dumps4Download. H12-425 Practice Test will provide you precisely adequate knowledge regarding exam topics, while Online Practice Test will give you training for predictable results in the final exam. All these preparation services due to experts who put their best for the best of IT candidates. When you download H12-425 Questions Answers, you also updated the study plan to be followed for the highest possible grades. You get a money-back guarantee on this platform that relaxes you about your payment. You are charged only if you get your wanted results. You must download free demo questions right now so that you can get an estimation about the worth of H12-425 Lab Questions.

Category Education

Comments

                     

Try Huawei H12-425 Dumps | H12-425 Verified Question Answers

Huawei H12-425 Dumps HCIP-Data Center Facility Deployment Verified By Experts Get Prepared And Pass Your Exam Teach Yourself Question: 1 Site selection is one challenge for the traditional data center A. TRUE B. FALSE Answer: A Question: 2 Unpredictable business, expansion and difficult investment is one of the challenges facing the development of traditional data center business. A. TRUE B. FALSE Answer: A Question: 3 Which system affects the PUE most in Data Center. A. Power Distribution system B. Cooling System C. N/A D. Lighting system Answer: B Question: 4 Which one is the best PUE in the following: A. 1.06 B. 2 C. 0.3 D. -0.5 Answer: A https://en.wikipedia.org/wiki/Power_usage_effectiveness Question: 5 Cold/Hot aisle containment is used to solve the problem of heat dissipation in Data Center. A. TRUE B. FALSE Answer: A Question: 6 Modular Data Center is on-demand deployment, which avoids over-investment. A. TRUE B. FALSE Answer: A Question: 7 Which Technologies or solutions can reduce PUE? A. Increasing the number of access control systems B. Efficient modular UPS C. Cold/hot aisle containment D. In-row cooling Answer: BCD Question: 8 FusionModule2000 is an outdoor smart modular data center solution. A. TRUE B. FALSE Answer: B FusionModule2000 is an indoor model Question: 9 FusionModule1000 is an indoor prefabricated all in-one data center solution. A. TRUE B. FALSE Answer: B FusionModule1000A All-in-One Prefabricated Data Center is a green and reliable outdoor data center solution. Question: 10 FusionModule1000A series solution meets the TIER 4 requirements if it adopts 2N power supply and distribution system. A. TRUE B. FALSE Answer: B (FM1000A does not support Tier 4) Question: 11 Depending on different layouts, the batteries can be deployed inside or outside FusionModule2000 A. TRUE B. FALSE Answer: A Question: 12 When ATS is in automatic mode, the handle for manual operation must be remove. A. TRUE B. FALSE Answer: A Question: 13 Smart Electricity meter of PDU8000 is abnormal, is it possible that: A. The transformation ratio of current or voltage is incorrectly set. B. Cables to the voltage collector are not properly connected. C. The current transformer is faulty. D. The smart electricity is faulty. Answer: ABCD Question: 14 Which kind of start-up principle does gas fire extinguishing system have? A. Automatic startup B. Emergency startup C. Safe startup D. Manual startup Answer: ABD Question: 15 If a fire occurs in the FusionModule1000, the smoke detector and heat detector will send a fire alarm to the fire alarm control panel. A. TRUE B. FALSE Answer: A